OBJECTIVE: To evaluate the image quality of low-dose temporal bone computed tomography (CT) in otitis media and mastoiditis patients by using deep learning reconstruction (DLR). MATERIALS AND METHODS: A total of ninety-seven temporal bones from 53 consecutive adult patients who had suspected otitis media and mastoiditis and underwent temporal bone CT were prospectively enrolled. All patients underwent high resolution CT protocol (group A) and an additional low-dose protocol (group B). In group A, high resolution data were reconstructed by filter back projection (FBP). In group B, low-dose data were reconstructed by DLR mild (B1), DLR standard (B2) and DLR strong (B3). The objective image quality was analyzed by measuring the CT value and image noise on the transverse image and calculating the signal-to-noise ratio (SNR) on incudomallear joint, retroauricular muscle, vestibule and subcutaneous fat. Subjective image quality was analyzed by using a five-point scale to evaluate nine anatomical structures of middle and inner ear. The number of temporal bone lesions which involved in five structures of middle ear were assessed in group A, B1, B2 and B3 images. RESULTS: There were no significant differences in the CT values of the four reconstruction methods at four structures (all p > 0.05). The DLR group B1, B2 and B3 had significantly less image noise and a significantly higher SNR than group A at four structures (all p < 0.001). The group B1 had comparable subjective image quality as group A in nine structures (all p > 0.05), however, the group B3 had lower subjective image quality than group A in modiolus, spiral osseous lamina and stapes (all p < 0.001), the group B2 had lower subjective image quality than group A in modiolus and spiral osseous lamina (both p < 0.05). The number of temporal bone lesions which involved in five structures for group A, B1 and B2 images were no significant difference (all p > 0.05), however, the number of temporal bone lesions which involved in mastoid for group B3 images were significantly more than group A (p < 0.05). The radiation dose of high resolution CT protocol and low-dose protocol were 0.55 mSv and 0.11 mSv, respectively. CONCLUSION: Compared with high resolution CT protocol, in the low-dose protocol of temporal bone CT, DLR mild and standard could improve the objective image quality, maintain good subjective image quality and satisfy clinical diagnosis of otitis media and mastoiditis patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。