Computational study on the transmission of the SARS-CoV-2 virus through aerosol in an elevator cabin: Effect of the ventilation system

电梯轿厢内SARS-CoV-2病毒气溶胶传播的计算研究:通风系统的影响

阅读:1

Abstract

Aerosol transmission is now well-established as a route in the spread of the SARS-CoV-2 virus. Factors influencing the transport of virus-laden particles in an elevator cabin are investigated computationally and include human respiratory events, locations of the infected person(s), and the ventilation system (ventilation mode, ventilation capacity, and vent schemes). "Breath," "cough," and "sneeze" are defined quantitatively by the fluid jet velocities and particle sizes. For natural ventilation, most particles exhaled by sneezing and coughing tend to deposit on surfaces quickly, but aerosol generated by breathing will remain suspended in the air longer. For forced ventilation, motions of particles under different ventilation capacities are compared. Larger particles otherwise deposited readily on solid surfaces may be slowed down by airflow. Air currents also accelerate the motions of smaller particles, facilitating the subsequent deposition of micrometer or sub-micrometer particles. Locations of the infected person(s) lead to different spreading scenarios due to the distinctive motions of the particles generated by the various respiratory events. Sneeze particles will likely contaminate the person in front of the infected passenger only. Cough particles will increase the risk of all the people around the injector. Breath particles tend to spread throughout the confined environment. An optimized vent scheme is introduced and can reduce particles suspended in the air by up to 80% as compared with commonly used schemes. The purification function of this vent model is robust to various positions of the infected passenger.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。