Comparison of Proposed Modified and Original Sequential Organ Failure Assessment Scores in Predicting ICU Mortality: A Prospective, Observational, Follow-Up Study

比较改良版序贯器官衰竭评估评分与原始评分在预测ICU死亡率方面的差异:一项前瞻性、观察性、随访研究

阅读:1

Abstract

Background. The sequential organ failure assessment (SOFA) score has been recommended to triage critically ill patients in the intensive care unit (ICU). This study aimed to compare the performance of our proposed MSOFA and original SOFA scores in predicting ICU mortality. Methods. This prospective observational study was conducted on 250 patients admitted to the ICU. Both tools scores were calculated at the beginning, 24 hours of ICU admission, and 48 hours of ICU admission. Diagnostic odds ratio and receiver operating characteristic (ROC) curve were used to compare the two scores. Results. MSOFA and SOFA predicted mortality similarly with an area under the ROC curve of 0.837, 0.992, and 0.977 for MSOFA 1, MSOFA 2, and MSOFA 3, respectively, and 0.857, 0.988, and 0.988 for SOFA 1, SOFA 2, and SOFA 3, respectively. The sensitivity and specificity of MSOFA 1 in cut-off point 8 were 82.9% and 68.4%, respectively, MSOFA 2 in cut-off point 9.5 were 94.7% and 97.1%, respectively, and MSOFA 3 in cut-off point of 9.3 were 97.4% and 93.1%, respectively. There was a significant positive correlation between the MSOFA 1 and the SOFA 1 (r: 0.942), 24 hours (r: 0.972), and 48 hours (r: 0.960). Conclusion. The proposed MSOFA and the SOFA scores had high diagnostic accuracy, sensitivity, and specificity for predicting mortality.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。