Integrated Purification Systems for the Removal of Disinfectants from Wastewater

用于去除废水中消毒剂的集成净化系统

阅读:1

Abstract

The efficiency of integrated treatment systems for wastewater generated during the washing of disinfectant production lines was investigated. The high organic load (COD 2000 mg/L, TOC 850 mg/L) and 300 mg/L of toxic benzalkonium chloride (BAC) make wastewater an environmental hazard that requires advanced treatment. Initial tests on model BAC solutions (in concentrations corresponding to those found in wastewater), using nanofiltration and ultrafiltration membranes, resulted in up to 70% retention of BAC. To enhance purification, ion exchange and adsorption were introduced as post-membrane treatment steps. In the second part of the investigation, membrane modules characterized by the best separation properties were integrated together with macroporous cation-exchange resin and activated carbon into the purification system to treat wastewater. The research carried out showed that the purification of multicomponent wastewater is a complex task. Significantly lower BAC removal (30%) was achieved in membrane processes compared to the model solutions treatment. In integrated systems, the BAC concentration was reduced to 100 mg/L, TOC to 200 mg/L, and COD to 120 mg/L.