Data from cryo-neutron phase change experiments with LH2 and LCH4

利用LH2和LCH4进行的低温中子相变实验数据

阅读:1

Abstract

Cryogenic Propellant management is a critical roadblock to enable long term space missions. Commonly used propellants (liquid hydrogen and methane) undergo constant vaporization but there is limited knowledge on the phase change rate and its implications on long term storage stability. This is, in part, due to the inability to image the liquid-vapor mixture inside opaque metallic containers at cryogenic temperatures. Here, neutron imaging is used as a visualization technique to track the liquid-vapor interface inside Al 6061 and SS 316 test cells. The data contains first known images of steady evaporation/condensation in cryogenic propellants. The experiments were conducted at the NIST Center for Neutron Research using the BT-2 Neutron Imaging facility. The test cells were instrumented with temperature sensors and inserted into a 70-mm liquid helium cryostat before being placed into the neutron beam. Temperatures and pressures were altered to achieve condensation/evaporation and Neutron images were captured during the entire phase change process. Phase change rates were obtained through image processing. The data contains raw images and processed phase change rates along with experimental temperature and pressure. The one-of-a-kind data could be used for model validation, correlation development or serve as a benchmark for future experiments.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。