A Large Measurable Range Capacitance-to-Digital Converter for Smart Humidity Sensors

用于智能湿度传感器的大测量范围电容式数字转换器

阅读:1

Abstract

This study aims to propose a capacitance-to-digital converter (CDC) based on a third-order cascade of integrators with a feed-forward (CIFF) incremental sigma-delta modulator for smart humidity sensor application. Disguised zoom-in technology was proposed to enlarge the measurable range of the CDC. The input range of the CDC was 0-388 pF. The proposed CDC was realized using 0.18 μm complementary metal-oxide-semiconductor technology. Results show that the CDC performs a 13-bit capacitance-to-digital conversion in 0.8 ms. The analog system consumes 169.7 μA from a 1.8 V supply, which corresponds to a figure of merit (FOM) of 3.0 nJ/step. The proposed CDC was combined with a HS1101 humidity sensor to demonstrate its incorporation in an overall system design. The resolution was 0.7% relative humidity (RH) over a range of 30%-90% RH.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。