High-Temperature Failure Evolution Analysis of K-Type Film Thermocouples

K型薄膜热电偶高温失效演化分析

阅读:1

Abstract

Ni90%Cr10% and Ni97%Si3% thin-film thermocouples (TFTCs) were fabricated on a silicon substrate using magnetron sputtering technology. Static calibration yielded a Seebeck coefficient of 23.00 μV/°C. During staged temperature elevation of the TFTCs while continuously monitoring their thermoelectric output, a rapid decline in thermoelectric potential was observed upon the hot junction reaching 600 °C; the device had failed. Through three cycles of repetitive static calibration tests ranging from room temperature to 500 °C, it was observed that the thermoelectric performance of the TFTCs deteriorated as the testing progressed. Utilizing the same methodology, Ni-Cr and Ni-Si thin films corresponding to the positive and negative electrodes of the TFTCs were prepared. Their resistivity after undergoing various temperature annealing treatments was measured. Additionally, their surfaces were characterized using Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). The causes behind the decline in thermoelectric performance at elevated temperatures were analyzed from both chemical composition and microstructural perspectives.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。