A Novel Temperature Drift Compensation Algorithm for Liquid-Level Measurement Systems

一种用于液位测量系统的新型温度漂移补偿算法

阅读:1

Abstract

Aiming at the problem that ultrasonic detection is greatly affected by temperature drift, this paper investigates a novel temperature compensation algorithm. Ultrasonic impedance-based liquid-level measurement is a crucial non-contact, non-destructive technique. However, temperature drift can severely affect the accuracy of experimental measurements based on this technology. Theoretical analysis and experimental research on temperature drift phenomena are conducted in this study, accompanied by the proposal of a new compensation algorithm. Leveraging an external fixed-point liquid-level detection system experimental platform, the impact of temperature drift on ultrasonic echo energy and actual liquid-level height is examined. Experimental results demonstrate that temperature drift affects the speed and attenuation of ultrasonic waves, leading to decreased accuracy in measuring liquid levels. The proposed temperature compensation method yields an average relative error of 3.427%. The error range spans from 0.03 cm to 0.336 cm. The average relative error reduces by 21.535% compared with before compensation, showcasing its applicability across multiple temperature conditions and its significance in enhancing the accuracy of ultrasonic-based measurements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。