Layout Dependence Stress Investigation in through Glass via Interposer Architecture Using a Submodeling Simulation Technique and a Factorial Design Approach

采用子模型仿真技术和因子设计方法研究玻璃通孔中介层架构中的布局依赖性应力

阅读:1

Abstract

The multi-chiplet technique is expected to be a promising solution to achieve high-density system integration with low power consumption and high usage ratio. This technique can be integrated with a glass interposer to accomplish a competitive low fabrication cost compared with the silicon-based interposer architecture. In this study, process-oriented stress simulation is performed by the element activation and deactivation technique in finite element analysis architecture. The submodeling technique is also utilized to mostly conquer the scale mismatch and difficulty in mesh gridding design. It is also used to analyze the thermomechanical responses of glass interposers with chiplet arrangements and capped epoxy molding compounds (EMC) during curing. A three-factor, three-level full factorial design is applied using the analysis of variance method to explore the significance of various structural design parameters for stress generation. Analytic results reveal that the maximum first principal stresses of 130.75 and 17.18 MPa are introduced on the sidewall of Cu-filled via and the bottom of the glass interposer, respectively. Moreover, the EMC thickness and through glass via pitch are the dominant factors in the adopted vehicle. They significantly influence the stress magnitude during heating and cooling.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。