Results From a Proficiency Testing Pilot for Immunosuppressant Microsampling Assays

免疫抑制剂微量采样试验能力验证试点结果

阅读:9
作者:Herman Veenhof, Remco A Koster, Lenneke A T Junier, Peter Zweipfenning, Daan J Touw

Background

Therapeutic drug monitoring (TDM) of immunosuppressive drugs is important for the prevention of allograft rejection in transplant patients. Several hospitals offer a microsampling service that provides patients the opportunity to sample a drop of blood from a fingerprick at home that can then be sent to the laboratory by mail. The

Conclusions

Immunosuppressant microsampling methods show great interlaboratory variation compared with whole blood methods. This variation can influence clinical decision-making. Thus, harmonization and standardization are needed. Proficiency testing should be performed regularly for laboratories that use immunosuppressant microsampling techniques in patient care.

Methods

Fourteen laboratories from 7 countries participated (fully or partly) in 3 rounds of proficiency testing for the immunosuppressants tacrolimus, ciclosporin, everolimus, sirolimus, and mycophenolic acid. The microsampling devices included the following: Whatman 903 and DMPK-C, HemaXis, Mitra, and Capitainer-B. All assays were based on liquid chromatography with tandem mass spectrometry. In round 2, microsamples as well as liquid whole blood samples were sent, and 1 of these samples was a patient sample.

Results

Imprecision CV% values for the tacrolimus microsamples reported by individual laboratories ranged from 13.2% to 18.2%, 11.7%-16.3%, and 12.2%-18.6% for rounds 1, 2, and 3, respectively. For liquid whole blood (round 2), the imprecision CV% values ranged from 3.9%-4.9%. For the other immunosuppressants, the results were similar. A great variety in analytical procedures was observed, especially the extraction method. For the patient sample, the microsample results led to different clinical decisions compared with that of the whole blood sample. Conclusions: Immunosuppressant microsampling methods show great interlaboratory variation compared with whole blood methods. This variation can influence clinical decision-making. Thus, harmonization and standardization are needed. Proficiency testing should be performed regularly for laboratories that use immunosuppressant microsampling techniques in patient care.