Umbilical cannulation optimizes circuit flows in premature lambs supported by the EXTra-uterine Environment for Neonatal Development (EXTEND)

脐带插管优化了早产羔羊的循环血流,这是由新生儿发育的子宫外环境(EXTEND)项目支持的。

阅读:1

Abstract

KEY POINTS: Bronchopulmonary dysplasia is a disease of extreme prematurity that occurs when the immature lung is exposed to gas ventilation. We designed a novel 'artificial womb' system for supporting extreme premature lambs (called EXTEND) that obviates gas ventilation by providing oxygen via a pumpless arteriovenous circuit with the lamb submerged in sterile artificial amniotic fluid. In the present study, we compare different arteriovenous cannulation strategies on EXTEND, including carotid artery/jugular vein (CA/JV), carotid artery/umbilical vein (CA/UV) and umbilical artery/umbilical vein (UA/UV). Compared to CA/JV and CA/UV cannulation, UA/UV cannulation provided significantly higher, physiological blood flows to the oxygenator, minimized flow interruptions and supported significantly longer circuit runs (up to 4 weeks). Physiological circuit blood flow in UA/UV lambs made possible normal levels of oxygen delivery, which is a critical step toward the clinical application of artificial womb technology. ABSTRACT: EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system that promotes physiological development by maintaining the premature lamb in a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit. During the development of EXTEND, different cannulation strategies evolved with the aim of improving circuit flow. The present study examines how different cannulation strategies affect EXTEND circuit haemodynamics in extreme premature lambs. Seventeen premature lambs were cannulated at gestational ages 105-117 days (term 145-150 days) and supported on EXTEND for up to 4 weeks. Experimental groups were distinguished by cannulation strategy: carotid artery outflow and jugular vein inflow (CA/JV; n = 4), carotid artery outflow and umbilical vein inflow (CA/UV; n = 5) and double umbilical artery outflow and umbilical vein inflow (UA/UV; n = 8). Circuit flows and pressures were measured continuously. As we transitioned from CA/JV to CA/UV to UA/UV cannulation, mean duration of circuit run and weight-adjusted circuit flows increased (P < 0.001) and the frequency of flow interruptions declined (P < 0.05). Umbilical vessels generally accommodated larger-bore cannulas, and cannula calibre was directly correlated with circuit pressures and indirectly correlated with flow:pressure ratio (a measure of post-membrane resistance). We conclude that UA/UV cannulation in fetal lambs on EXTEND optimizes circuit flow dynamics and flow stability and also supports circuit flows that closely approximate normal placental flow.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。