Experimental data on open circuit voltage characterization for Li-ion batteries

锂离子电池开路电压特性实验数据

阅读:1

Abstract

In this article, we present the datasets collected from nine different Li-ion batteries. These datasets contain voltage, current and time measurements during a full charge-discharge cycle of a battery at very low current (that is nearly at C/30 rate). Such low current rate data is suitable for open circuit voltage characterization. The collection of this data was done through the use of an Arbin battery cycler and a thermal chamber was used to control the test temperature. Data were collected over a wide range of temperatures from - 25 ∘ C to 50 ∘ C.