Experience with Optical Coherence Tomography Enhanced by a Novel Software (Ultreon™ 1.0 Software)-The First One Hundred Cases

利用新型软件(Ultreon™ 1.0 软件)增强光学相干断层扫描技术的经验——前一百例病例

阅读:1

Abstract

Introduction: Optical coherence tomography (OCT) intravascular imaging including the latest version Ultreon™ 1.0 Software (Abbott Vascular, Santa Clara, CA, USA), not only improve patients prognosis, but also facilitates improved percutaneous coronary intervention (PCI). Objectives: The aim of the study was to compare procedure related decision making, procedural indices, clinical outcomes according to the extent of stent expansion and assess risk factors of underexpansion in patients treated with PCI using OCT. Methods: The study comprised 100 patients, which were divided in groups according to the extent of stent expansion: <90 (29 patients) and ≥90% (71 patients). Comparison of OCT parameters, selected clinical and procedural characteristics was performed between groups. We assessed clinical outcomes during the follow-up: major adverse cardiovascular events and risk factors of stent underexpansion. Results: Patients from the stent underexpansion group were treated more often in the past with percutaneous peripheral interventions (p=0.02), no other significant differences being noted in general characteristics, procedural characteristics or clinical outcomes comparing both groups. Significant predictors of stent underexpansion assessed by simple linear univariable analysis included: hypercholesterolemia, obstructive bronchial diseases and treatment with inhalators, family history of cardiovascular disease, PCI of other than the left main coronary artery, stent and drug-eluting stent implantation, PCI without drug-eluting balloon, paclitaxel antimitotic agent, greater maximal stent diameter and lower mean Euroscore II value. Univariable logistic regression analysis revealed a correlation between stent underexpansion and greater creatinine serum concentration before [OR: 0.97, 95%CI: 0.95-0.99, p=0.01] and after PCI [OR: 0.98, 95%CI: 0.96-0.99, p=0.02]. Conclusions: Based on the presented analysis, the degree of stent expansion is not related to the selected procedural, OCT imaging indices and clinical outcomes. Logistic regression analysis confirmed such a relationship for creatinine level.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。