Using an Electromyography Method While Measuring Oxygen Uptake to Appreciate Physical Exercise Intensity in Adolescent Cyclists: An Analytical Study

利用肌电图法测量氧气摄取量以评估青少年自行车运动员运动强度:一项分析研究

阅读:1

Abstract

Background and Objectives: During physical exercise, the electrical signal of the muscle fibers decreases due to repeated muscle contractions held at different intensities. The measured signal is strongly related to the motor unit activation rate, which is dependent on the chemical mediators and the available energy. By reducing the energy availability, adenosine triphosphate (ATP) production will decrease and therefore the muscle fibers activation rate will be negatively affected. Such aspects become important when taking into account that the training intensity for many young athletes is rather controlled by using the heart rate values. Yet, on many occasions, we have seen differences and lack of relationship between the muscle activation rate, the heart rate values and the lactate accumulation. Materials and Methods: We conducted a prospective analytical study conducted during a 4-month period, on a sample of 30 participants. All study participants underwent an incremental exercise bike test to measure maximum aerobic capacity as well as the muscle activation rate in the vastus lateralis by using an electromyography method (EMG). Results: With age, the EMG signal dropped, as did the electromyography fatigue threshold (EMG(FT)) point, as seen through p = 0.0057, r = -0.49, CI95% = -0.73 to -0.16, and electromyography maximum reached point (EMG(MRP)) (p = 0.0001, r = -0.64, CI95% = -0.82 to -0.36), whereas power output increased (p = 0.0186, r = 0.427). The higher the power output, the lower the signal seen by measuring active tissue EMG(FT) (p = 0.0324, r = -0.39) and EMG(MRP) (p = 0.0272, r = -0.40). Yet, with changes in median power output, the power developed in aerobic (p = 0.0087, r = 0.47), mixed (p = 0.0288, r = 0.39), anaerobic (p = 0.0052, r = 0.49) and anaerobic power (p = 0.004, r = 0.50) exercise zones increased. Conclusions: There has been reported a relationship between aerobic/anaerobic ventilatory thresholds (VT(1) and VT(2)) and EMG(FT), EMG(MRP), respectively. Each change in oxygen uptake increased the power output in EMG(FT) and EMG(MRP), improving performances and therefore overlapping with both ventilatory thresholds.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。