Augmentation of rotator cuff repair with gelatin-resorcin-formalin glue: a biomechanical study

明胶-间苯二酚-福尔马林胶增强肩袖修复:一项生物力学研究

阅读:1

Abstract

INTRODUCTION: Rotator cuff tendons are typically reattached to the proximal humerus using transosseous sutures or suture anchors. Their primary mode of failure is at the tendon-bone interface. METHODS: We investigated the addition of an adhesive, gelatin-resorcin-formalin (GRF) glue, to a single-row rotator cuff repair (RCR) on ex vivo sheep models. We hypothesised the addition of GRF glue would increase the repair construct strength. The study consisted of three groups of six sheep infraspinatus tendons with an inverted-mattress stitch, tension-band configuration. Group 1 was the control group where no glue was applied. Group 2 involved applying 2 × 2 cm of GRF glue to the infraspinatus footprint and a 2-min curing time. Group 3 allowed for a 15-min cure time. RESULTS: Failure occurred at the tendon-bone-suture interface in 6/6 of the control group, and 4/6 from groups 2 and 3. Failure occurred via the suture pulling out of the anchor in 2/6 of groups 2 and 3. No significant differences were noted between all three groups in ultimate failure load, repair stiffness or total energy to failure (p > 0.05). DISCUSSION: The addition of GRF glue to the tendon-bone-suture interface did not enhance RCR strength in an ovine model.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。