Accurate measurement of androgen after androgen esters: problems created by ex vivo esterase effects and LC-MS/MS interference

雄激素酯后雄激素的准确测量:体外酯酶效应和 LC-MS/MS 干扰引起的问题

阅读:6
作者:J Ceponis, R Swerdloff, A Leung, L Hull, F Bai, J Longstreth, R Dudley, T Danoff, C Wang

Background

Ex vivo androgen prodrug conversion by blood esterases after oral androgen ester administration may result in an overestimation of the measured blood androgens.

Conclusion

NaF directly lowers plasma T/DMA levels measured by LC-MS/MS and also inhibits blood esterase activity. Overestimation of T/DMA in blood collected in tubes without NaF after oral TU/DMAU administration is important for pharmacokinetics studies in drug development clinical trials but may have limited impact in clinical practice/utilization because the differences between measured and true androgen values are modest and the wide therapeutic androgen efficacy ranges obviate the need for highly accurate androgen measurements during therapy.

Methods

Blood was collected in tubes with/without esterase inhibitors from: (i) four healthy and four hypogonadal men receiving no androgens and spiked ex vivo with TU/DMAU; (ii) four men taking oral TU (Andriol® ); and (iii) eight hypogonadal men dosed with oral 316 mg TU and 15 healthy men with 200 mg DMAU. T/DMA levels were measured by LC-MS/MS.

Objective

We investigated whether blood collection tubes with esterase inhibitors decreased the conversion of testosterone undecanoate (TU) and dimethandrolone undecanoate (DMAU) to their active metabolites, testosterone (T), and dimethandrolone (DMA), providing a more accurate assessment of circulating T/DMA levels.

Results

Sodium fluoride (NaF, an esterase inhibitor) decreased measured T levels by 14.2% in men not receiving TU. Increasing amounts of TU/DMAU added to blood collected into plain tubes resulted in a concentration-dependent overestimation of T/DMA that was reduced by collecting blood into NaF tubes (by 30-85%), and keeping samples at 4 °C and minimizing time prior to centrifugation. After oral TU/DMAU administration to men, when TU/DMAU levels were >15/10 ng/mL, respectively, blood collected in NaF tubes yielded lower measured T concentrations by 15-30% and DMA by 22% due to an additional inhibitory effect of NaF on blood esterases.