Accuracy of shoulder joint injections with ultrasound guidance: Confirmed by magnetic resonance arthrography

超声引导下肩关节注射的准确性:经磁共振关节造影证实

阅读:1

Abstract

BACKGROUND: Intra-articular glenohumeral joint injections are essential procedures for treating various shoulder disorders. Fluoroscopy-guided injections have been extensively used; however, they pose a risk of radiation exposure and are expensive and time-consuming. Recently, it has been suggested that ultrasound-guided injections are accurate and cost effective procedures. AIM: To evaluate the accuracy of ultrasound-guided glenohumeral injections using a posterior approach that is confirmed using magnetic resonance arthrography (MRA). METHODS: The study included 179 shoulders of patients with recurrent anterior instability (150 patients; 103 and 76 right and left shoulders, respectively; 160 males and 19 females; average age = 20.5 years; age range: 14-63 years) who underwent MRA for preoperative diagnosis. They were injected with 12 mL lidocaine (1%) using the ultrasound-guided posterior approach and then underwent magnetic resonance imaging. Two shoulder surgeons, except for the injector, evaluated the transverse relaxation (T2)-weighted images of axial planes and classified the intra-articular condition of injected contrast into three groups based on one of the three following scenarios: no leakage, injection into the glenohumeral joint without leakage; minor leakage, practical intra-articular injection with some leakage outside the posterior rotator cuffs; and major leakage, inaccurate injection with mass leakage without any contrast into the joint. The inter-rater reliability between two assessors was also evaluated by calculating Cohen's kappa coefficient. The learning curve was assessed regarding the inaccurate injection rate by analyzing Spearman's rank correlation coefficient. RESULTS: Of the 179 injections, 163 shoulders (91.0%) had no leakage, 10 shoulders (5.6%) had minor leakage, and six shoulders (3.4%) had major leakage. In total, 173 shoulders (96.6%) were intra-articularly injected; thus, we could detect anterior labrum and capsular pathologies. Regarding the inter-rater reliability, the kappa coefficient was 0.925, indicating consistency in the evaluations by both examiners. Regression analysis of the inaccurate injection rate for assessingtechnical learning showed a logarithmic curve with a downward trend (R(2) = 0.887, P < 0.001). Three (50%) of the six inaccurate injections classified into "major leakage" were observed in the first 30 injections, indicating that the accurate injection showed a leaning effect. CONCLUSION: Ultrasound-guided intra-articular glenohumeral injections using a posterior approach had high accuracy; however, injection accuracy depends on clinical experience.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。