Acid-fast microscopy on polycarbonate membrane filter sputum sediments

聚碳酸酯膜过滤器痰沉淀物的抗酸显微镜检查

阅读:1

Abstract

Polycarbonate membrane filters were used to concentrate 916 sputum specimens for detecting acid-fast bacilli by microscopic examination. These results were compared with those of smears prepared from centrifugates and direct smears of the same specimens. Culture isolation, the control procedure, demonstrated the presence of acid-fast bacilli in 76 specimens. The number of positive specimens detected by microscopy was 82 on polycarbonate membrane filter concentrates, with an 80.2% sensitivity; 53 on centrifugate smears, with a 62.2% sensitivity; and 44 on direct smears, with a 55.8% sensitivity. Acid-fast microscopy results demonstrated that the sensitivity of the polycarbonate membrane filter sputum concentration method was superior to that of the recommended centrifuge concentration method and that the former method may be considered a rapid alternative when culture for acid-fast bacilli is impractical.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。