Evaluation of the Validity of Digital Optical Microscopy in the Assessment of Marginal Adaptation of Dental Adhesive Interfaces

数字光学显微镜在评估牙科粘接剂界面边缘适应性中的有效性评价

阅读:1

Abstract

Analysis of marginal adaptation of dental adhesive interfaces using scanning electron microscopy has proven to be a powerful nondestructive method to evaluate the quality of adhesion. This methodology is, however, time-consuming and needs expensive equipment. The purpose of this study was to evaluate the possibility and efficiency of using a digital optical microscope (DOM) to perform marginal analysis and to compare it with the scanning electron microscope (SEM) analysis. Fifteen defect-free molars were selected for this study. Class V cavities were prepared and restored with resin composite, and epoxy replicas were obtained from silicone impressions of the restored teeth. Custom-made image analysis software was then used to measure the percentage of the noncontinuous margins (NCM) of each sample. To compare the DOM to the gold standard, SEM, each sample was analyzed 10 times using the DOM and three times using the SEM, by the same experienced operator. The repeatability coefficient and concordance were evaluated, and a Bland and Altman analysis was used for comparison of the two methods of measurements. To validate the DOM analysis method, an ANOVA approach (Gage R R) was used. Repeatability and reproducibility, which are two components of precision to validate the DOM analysis system, were calculated. For this, the same restorations were analyzed by two additional operators three times with the DOM. The duration of each step of the analysis using both methods was also recorded as a secondary outcome. Regarding the repeatability of each method, the Friedman test showed no statistically significant difference within the repetitions of measurements by SEM and DOM (p = 0.523 and p = 0.123, respectively). Moreover, the Bland-Altman analysis revealed a bias of 0.86 and concluded no statistically significant difference between the two methods, DOM and SEM. ANOVA evaluated DOM measurement system variation including the variances of repeatability and reproducibility that represented, respectively, 0.3% and 4% of the variance components. Reproducibility or inter-operator variability represented the principal source of variability with a statistically significant difference (p = 0.024). The time required for analysis with SEM was almost double that of DOM. The use of digital optical microscopy appears to be a valid alternative to the SEM for the analysis of marginal adaptation of dental adhesive interfaces. Further studies to evaluate the effect of training of operators in digital optical microscopy could reveal higher accuracy for this method and inter-operator agreement when experience is gained.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。