Half a decade of mini-pool nucleic acid testing: Cost-effective way for improving blood safety in India

五年微池核酸检测:提高印度血液安全的经济有效方法

阅读:7
作者:Shivaram Chandrashekar

Conclusion

NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield) will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment.

Methods

Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR). Testing was done in mini-pools of size eight (8). Positive pools were repeated with individual samples.

Results

During the study period of Oct 2005-Sept 2010 (5 years) all blood donors (n=53729) were screened by ELISA. Of which 469 (0.87%) were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260) were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1) and HBV NAT yield (n=2) was 1/26630.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。