Impact of COVID-19 on the association between pulse oximetry and arterial oxygenation in patients with acute respiratory distress syndrome

COVID-19 对急性呼吸窘迫综合征患者脉搏血氧饱和度与动脉氧合关系的影响

阅读:8
作者:Lee S Nguyen #, Marion Helias #, Lisa Raia, Estelle Nicolas, Paul Jaubert, Sarah Benghanem, Zakaria Ait Hamou, Pierre Dupland, Julien Charpentier, Frédéric Pène, Alain Cariou, Jean-Paul Mira, Jean-Daniel Chiche, Mathieu Jozwiak

Abstract

Managing patients with acute respiratory distress syndrome (ARDS) requires frequent changes in mechanical ventilator respiratory settings to optimize arterial oxygenation assessed by arterial oxygen partial pressure (PaO2) and saturation (SaO2). Pulse oxymetry (SpO2) has been suggested as a non-invasive surrogate for arterial oxygenation however its accuracy in COVID-19 patients is unknown. In this study, we aimed to investigate the influence of COVID-19 status on the association between SpO2 and arterial oxygenation. We prospectively included patients with ARDS and compared COVID-19 to non-COVID-19 patients, regarding SpO2 and concomitant arterial oxygenation (SaO2 and PaO2) measurements, and their association. Bias was defined as mean difference between SpO2 and SaO2 measurements. Occult hypoxemia was defined as a SpO2 ≥ 92% while concomitant SaO2 < 88%. Multiple linear regression models were built to account for confounders. We also assessed concordance between positive end-expiratory pressure (PEEP) trial-induced changes in SpO2 and in arterial oxygenation. We included 55 patients, among them 26 (47%) with COVID-19. Overall, SpO2 and SaO2 measurements were correlated (r = 0.70; p < 0.0001), however less so in COVID-19 than in non-COVID-19 patients (r = 0.55, p < 0.0001 vs. r = 0.84, p < 0.0001, p = 0.002 for intergroup comparison). Bias was + 1.1%, greater in COVID-19 than in non-COVID-19 patients (2.0 vs. 0.3%; p = 0.02). In multivariate analysis, bias was associated with COVID-19 status (unstandardized β = 1.77, 95%CI = 0.38-3.15, p = 0.01), ethnic group and ARDS severity. Occult hypoxemia occurred in 5.5% of measurements (7.7% in COVID-19 patients vs. 3.4% in non-COVID-19 patients, p = 0.42). Concordance rate between PEEP trial-induced changes in SpO2 and SaO2 was 84%, however less so in COVID-19 than in non-COVID-19 patients (69% vs. 97%, respectively). Similar results were observed for PaO2 regarding correlations, bias, and concordance with SpO2 changes. In patients with ARDS, SpO2 was associated with arterial oxygenation, but COVID-19 status significantly altered this association.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。