A multiple regression based method for indirect compensation of hemispherical resonator gyro temperature error

一种基于多元回归的半球谐振器陀螺仪温度误差间接补偿方法

阅读:1

Abstract

In order to improve the measuring accuracy of the Hemispherical Resonator Gyro under variable temperature, aiming at the problem of "external temperature is unavailable and internal temperature is unmeasurable," a multiple regression based method is proposed for compensating temperature error in the gyro. The relationship between the internal temperature and the resonant frequency of the gyro is analyzed theoretically. According to a constant temperature experiment, a linear relationship between them is derived based on the least square method. The analysis of a temperature-rising experiment shows that the correlation of the gyro output with the internal temperature is much higher than that with the external temperature. Therefore, taking the resonant frequency as an independent variable, a multiple regression model is established for compensating the temperature error. The compensation effect of the model is verified by temperature-rising and temperature-dropping experiments, which show that the output sequence before compensation is not stable, while it is stable after compensation. After compensation, the drift of the gyro decreases by 62.76% and 48.48%, respectively, and its measuring accuracy becomes equivalent to that at the constant temperature. The experimental results verify the feasibility and effectiveness of the model developed for indirect compensation of temperature error.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。