Awake Fibreoptic Intubation for Forearm Injury in a Patient with Occipito-Cervical Fixator

对一名使用枕颈固定器治疗前臂损伤的患者进行清醒状态下的纤维支气管镜插管

阅读:1

Abstract

A 23-year-old male patient with occipitocervical fixator was scheduled for surgery due to injury to the right forearm. The patient's thyromental distance was 5 cm, mouth opening grade II, sternomental distance 10 cm and Mallampati score 4. Loss of extension and rotation movements of the head was assessed as difficult intubation criteria. Anaesthetic procedures are almost always difficult in patients with occipitocervical fixation; the limited cervical extension complicated both intubation and ventilation. In this report, application of general anaesthesia using awake fibreoptic bronchoscopic intubation (FOB) is described. After routine monitoring of vital signs and premedication, hypopharyngeal topical anaesthesia was accomplished by instilling 10% lidocaine spray twice via the appropriate nostril. Superior laryngeal nerve block was performed with local anaesthetic infiltration of tissues 1 cm below the greater horns of the hyoid bone. Lingual and pharyngeal branches of the glossopharyngeal nerve were blocked. Transtracheal block was performed. Following completion of local anaesthesia, the patient was intubated using the awake FOB technique, on 5 L min(-1) of 100% O2. After muscle relaxation, the patient underwent a microsurgical operation to repair eight tendons, one artery, and one nerve. Surgery lasted for 5 hours. When the extubation criteria were met, the patient was extubated. In cases of occipitocervical fixation, which causes severe limitation of neck movements, the use of awake fibreoptic intubation should be considered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。