Deterioration of Retinal Blood Flow Parameters in Branch Retinal Vein Occlusion Measured by Doppler Optical Coherence Tomography Flowmeter

多普勒光学相干断层扫描血流仪测量分支视网膜静脉阻塞时视网膜血流参数的恶化

阅读:1

Abstract

BACKGROUND: Doppler optical coherence tomography (DOCT) flowmeter can be used to measure retinal blood flow (RBF) parameters, including vessel diameter, blood velocity, and the absolute value of RBF within 2.0 s. We investigated the RBF parameters in eyes with branch retinal vein occlusion (BRVO) using a DOCT flowmeter. METHODS: Seventeen patients with unilateral BRVO were enrolled. All subjects underwent comprehensive ophthalmologic examinations. The RBF parameters were assessed from three veins, i.e., (1) an occluded vein, (2) a non-occluded vein in the BRVO eyes, and (3) an equivalent (superior or inferior) vein in the fellow eye (non-affected vein), using prototype DOCT flowmeter (Topcon, Tokyo, Japan). Moreover, the correlation between RBF parameters and the best corrected visual acuity (BCVA) was examined. We investigated the correlation between (1) the RBF parameters and the time from the initial visit, (2) the RBF parameters and the time from the last injection, and (3) the RBF parameters and the number of anti-vascular endothelial growth factor injections (VEGF). RESULTS: The diameter of the occluded vein (95.9 ± 24.7 µm) was smaller than that of the non-occluded vein (127.9 ± 23.7 µm) and that of the healthy veins (116.4 ± 13.9 µm). The RBF was lower in the occluded veins (4.7 ± 3.7 µL/min) than that in the non-occluded veins (10.3 ± 5.1 µL/min; p < 0.01) and in the fellow eyes (8.6 ± 4.0 µL/min; p = 0.013). In contrast, the blood velocity was not significantly different among the three types of veins. BCVA was correlated with the diameter of the occluded vein (ρ = 0.711, p = 0.001) but not with the RBF and blood velocity. The time from the initial visit, the time from the last injection, and the total number of anti-VEGF injections were not associated with any RBF parameters on the occluded vein. CONCLUSIONS: The RBF was significantly lower in the occluded veins than that in the other veins, and the diameter of the occluded vein was significantly smaller than that of the other veins in patients with BRVO. However, neither the time from the initial visit, nor the time from the last injection, nor the number of anti-VEGF injections were correlated with the RBF parameters on the occluded vein.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。