Analysis of the Significance of Changes in the Number and Energy Parameters of Acoustic Emission Signals on the Assessment of the Strength of Fibre-Cement Boards

分析声发射信号数量和能量参数变化对纤维水泥板强度评价的影响

阅读:1

Abstract

The article presents the results of three-point bending tests carried out for samples cut from full-size fibre-cement boards subjected to typical and exceptional conditions. The tests were carried out with the simultaneous acquisition of acoustic emission signals. It has been noted that some factors significantly deteriorate the strength parameters of the samples as well as cause the occurrence of differences in the number of acoustic emission signals of various classes and their energy parameters. A statistical analysis was carried out in order to repeat the relationship between the strength parameters of the samples and the acoustic emission parameters. Based on the research, it was found that the MOR bending strength for specimens exposed to fire and high temperature is more than 50% lower than for air-dried specimens and specimens exposed to water. The increased number of freeze-thaw cycles also has an impact on the strength of the specimens. Components exposed to more than 10 freeze-thaw cycles had a strength more than 30% smaller than the reference specimens soaked in water and exposed to bath-drying cycles. A similar dependency was indicated by the number of signals of the individual classes, their energy parameters and their frequencies. The number, strength, duration and frequency also decreased along with the increase in the test case number. On this basis, conclusions were drawn concerning the suitability of acoustic emission for the evaluation of the strength of fibre-cement elements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。