PURPOSE The aim of this study was to evaluate the diagnostic performance of iodine uptake parameters using dual-energy computed tomography (DECT) in discriminating inflammatory nodules from malignant tumors. METHODS This retrospective study included 116 solid pulmonary nodules from 112 patients who were admitted to our hospital between January and September 2018. All nodules were confirmed by surgery or puncture. The degree of enhancement of a single-section region of interest was evalu ated. After total tumor volume-of-interest segmentation, the mean iodine density of the whole tumor was measured. Meanwhile, iodine uptake parameters, including total iodine uptake vol ume, total iodine concentration, vital iodine uptake volume, and vital iodine concentration, were calculated, and a predictive model was established. The overall ability to discriminate between inflammatory and malignant nodules was analyzed using an independent samples t-test for normally distributed variables. The diagnostic accuracy and prognostic performance of DECT parameters were evaluated and compared using receiver operating characteristic curve analysis and logistic regression analysis. A multivariate logistic regression analysis was used to determine the prognostic factors and goodness-of-fit of the whole tumor mean iodine and iodine uptake parameters for discriminating malignant nodules. RESULTS There were 116 non-calcified nodules, including 64 inflammatory nodules and 52 malignant nodules. The degree of enhancement in malignant nodules was significantly lower than that in inflammatory nodules (P=.043). All iodine uptake parameters in malignant nodules were signifi cantly higher than those in inflammatory nodules (P < .001). The area under the receiver operat ing curve value, accuracy, sensitivity, and specificity of the established model based on iodine uptake parameters were 0.803, 76.72%, 82.69%, and 84.37%, respectively, which exhibited bet ter diagnostic performance than the degree of enhancement on weighted average images with respective values of 0.609, 59.48%, 61.54%, and 59.38%. CONCLUSION The iodine uptake parameters of DECT exhibited better diagnostic accuracy in discriminating inflammatory nodules from malignant nodules than the degree of enhancement on weighted average images.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。