MR cine DENSE dyssynchrony parameters for the evaluation of heart failure: comparison with myocardial tissue tagging

MR cine DENSE 不同步参数在心力衰竭评估中的应用:与心肌组织标记的比较

阅读:2

Abstract

OBJECTIVES: We sought to assess the effectiveness of automated mechanical dyssynchrony (MD) parameters based on regional heterogeneity of strain (circumferential [CURE], longitudinal [LURE], and radial uniformity ratio estimates) relative to parameters based on regional time to peak contraction with cardiac magnetic resonance (CMR) cine DENSE (Displacement Encoding with Stimulated Echoes) validated with myocardial tissue tagging (MTT) strain data. BACKGROUND: Dyssynchrony measures based on the Fourier transformation (FT) of regional strain, such as CURE (previously evaluated in cardiac resynchronization therapy candidates), directly assess MD and yield straightforward global dyssynchrony indexes; however, performance relative to the 12-segment standard deviation of time to peak strain (SD12) or maximal regional delay in time to peak strain is unknown. METHODS: Cine DENSE and MTT were obtained with CMR (1.5-T Siemens Avanto, Siemens, Erlangen, Germany) in 13 canines: 3 normal control subjects, 5 with tachycardia pacing-induced heart failure (HF) and left bundle branch ablation (LBBB-HF), and 5 with HF and narrow QRS (NQRS-HF). Strain and dyssynchrony parameters were determined with both CMR methods. RESULTS: Both HF groups had reduced peak strains and left ventricular ejection fraction compared with normal cases. There was strong agreement between cine DENSE and MTT on the basis of intraclass correlation coefficients (CURE: 0.99, 95% CI: 0.96 to 1.00; LURE: 0.92, 95% CI: 0.77 to 0.98; circumferential strain [E(CC)]: 0.95, 95% CI: 0.72 to 0.99; longitudinal strain [E(LL)]: 0.82, 95% CI: 0.42 to 0.97). The FT-based metrics (scale 0 to 1), in particular CURE, discriminated highly between LBBB-HF and NQRS-HF groups (median difference): CURE: 0.60, 95% CI: 0.43 to 0.76; LURE: 0.39, 95% CI: 0.19 to 0.58; radial uniformity ratio estimate: 0.22, 95% CI: 0.04 to 0.40). In contrast, relative confidence intervals for group differences in time-to-peak parameters were wide, indicating less consistent discrimination (median difference): SD12-E(CC): 52.5, 95% CI: -4.0 to 109.2; SD12-E(LL): 40.9, 95% CI: -5.3 to 87.1; SD12-radial strain: 42.0, 95% CI: 0.4 to 83.6). Correlations between FT-based and time-to-peak parameters were significant (CURE/SD12-E(CC): r = -0.62, p = 0.03; LURE/SD12-E(LL): r = -0.76, p = 0.005) but not as tight as correlations between time-to-peak parameters. CONCLUSIONS: Automated FT-based circumferential, radial, and longitudinal dyssynchrony measures compare favorably with time-to-peak parameters. Cine DENSE was effective for this application and validated with MTT. Further clinical evaluation in cardiac resynchronization therapy candidates with CMR or other imaging modalities is warranted.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。