Reliability and validity of a video-based markerless motion capture system in young healthy subjects

在年轻健康受试者中,基于视频的无标记运动捕捉系统的可靠性和有效性

阅读:1

Abstract

BACKGROUND: Gait analysis is widely utilized for the diagnosis and prognosis of various diseases. Recently, innovative convenient markerless motion capture systems have been developed to replace the traditional marker-based three-dimensional motion capture systems. PURPOSE: s:This study is to evaluate the test-retest reliability of a novel video-based markerless motion capture system(Watrix, China) and to assess its concordance with a three-dimensional motion analysis system (BTS, Italy) in a population of young healthy subjects. PARTICIPANTS AND METHODS: Our study included 36 healthy adult participants. Each subject underwent three assessments using Watrix system and BTS system. To evaluate the validity and reliability of the measurements, we employed paired-sample t-tests, Wilcoxon signed-rank tests, intra-class correlation coefficients, Bland-Altman analysis and Passing Bablok regression analysis. RESULTS: Both intra-rater and inter-rater reliability demonstrated moderate to excellent correlations, with intraclass correlation coefficient (ICC) values ranging from 0.507 to 0.936, except for cadence(ICC = 0.233). The validity exhibited a good correlation for sagittal plane parameters(ICC ranging from 0.818 to 0.883) and a moderate correlation for the coronal and transverse parameters (ICC ranging from 0.520 to 0.608). The Passing Bablok linear regression analysis indicated that the confidence intervals for the intercepts of all parameters included 0, while the confidence intervals for the slopes of most parameters encompassed 1 except for step width, pelvic obliquity, and hip adduction-abduction angle. The implementation of Watrix system significantly decreased the testing duration for participants. CONCLUSIONS: The Watrix system demonstrated relatively high test-retest reliability. The Watrix and BTS systems demonstrated moderate to good agreement for most parameters. However, the Watrix system tended to underestimate coronal and transverse plane parameters, resulting in lower consistency. In addition, the markerless motion capture system greatly reduces the testing duration.Optimizing algorithms to improve recognition accuracy remains the main direction of research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。