Anterior Chamber Biometric Parameters Associated With Intraocular Pressure Reduction After Phacoemulsification in Non-Glaucomatous Eyes With Open Angles

非青光眼性开角型青光眼患者行超声乳化术后眼压降低相关的前房生物测量参数

阅读:3

Abstract

BACKGROUND: Decreased intra-ocular pressure after cataract surgery has been reported in eyes with and without glaucoma with variable magnitude. It is influenced by the anatomical structure of the anterior chamber. Preoperative evaluation of anterior chamber parameters can help to predict the change in intra-ocular pressure postoperatively. OBJECTIVE: The objective of the study is to evaluate intraocular pressure (IOP) change after uneventful phacoemulsification in non-glaucomatous eyes with open angles and its correlation with preoperative anterior chamber parameters measured by anterior segment optical coherence tomography (AS-OCT). METHODS: In this hospital-based prospective observational study, we included consecutive patients without glaucoma and open angles on gonioscopy who had undergone uncomplicated phacoemulsification with intraocular lens implantation (IOL). IOP and anterior chamber biometric parameters were measured preoperatively and compared with parameters obtained three months post-operatively by AS-OCT. The change in IOP and its relation to the parameters, including anterior chamber angle (ACA), anterior chamber depth (ACD), angle opening distance 500 μm anterior to the scleral spur (AOD500), anterior chamber width (ACW), lens vault (LV), and trabecular iris space area (TISA500) were evaluated. The main outcome measure was a change in IOP after phacoemulsification in normal eyes. RESULTS: Sixty-four eyes of 64 patients were enrolled. The mean patient age was 58.5 ± 9.4 years. The average IOP reduction was 2.43±1.64 mm of Hg from a preoperative mean of 16.77±2.54 mmHg three months after phacoemulsification surgery. The mean AOD500 increased significantly (0.440 ± 0.07 to 0.522 ±0.092) from preoperatively to three months postoperatively (p < 0.001). Preoperative lens vault and preoperative IOP had a strong positive correlation with the change in IOP at three months (r-value = 0.606; p-value <0.001) and (r-value = 0.73; p-value <0.001). There was a significant negative correlation between pre-operative TISA and AOD with change in IOP at three months (r-value = -0.545; p-value <0.001) and (r-value = -0.69; p-value <0.01). CONCLUSION:  Phacoemulsification surgery results in IOP reduction in non-glaucomatous eyes. Pre-operative IOP, lens vault, AOD, and TISA were significant predictors for IOP reduction.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。