Commercial suture passer improves efficiency and ease of use versus conventional needle in minimally invasive thoracolumbar fascia closure: a cadaveric analysis

一项尸体分析表明,在微创胸腰筋膜缝合术中,商用缝合器相比传统缝合针可提高效率和易用性。

阅读:1

Abstract

BACKGROUND: Low-profile suture passers have been introduced to facilitate thoracolumbar fascia closure in minimally invasive spine (MIS) surgery. The purpose of this study was to evaluate the closure time of a modern suture passer to a conventional curved need for MIS fascia closure in a cadaveric model. METHODS: Six clinicians specializing in orthopedic spine surgery were recruited for the study and randomly assigned 1 cadaveric torso. Subcutaneous tissue was resected at L4-L5, replicating MIS surgery, followed by placement of a 60×18-mm or 100×18-mm tubular retractor for access. Clinicians were required to close the fascia with three unknotted, simple interrupted sutures using a swaged curved needle or suture passer (Spine Scorpion™, Arthrex, Inc., Naples, FL). The completion time was recorded, starting immediately before suturing and ending after the last pass. A time cutoff of 10 min was implemented in consideration of reasonable operating room time, and the number of achieved suture passes (of 6) were recorded. Clinicians were asked to qualitatively grade ease of use in relation to prior fascial closure experience per a 0-5 scale, where 0 is impossible and 5 is easiest. RESULTS: The mean change in fascial closure completion time (Δ) was significantly reduced with the Spine Scorpion compared to the curved needle with the 60×18-mm retractor (Δ=5.80 min; 95% CI, 2.92-8.67 min; p=.004) and 100 × 18-mm retractor (Δ=5.28 min; 95% CI, 2.76-7.80 min; p=.003). Full closure was achieved within the time limit for all trials of the Spine Scorpion, while the standard needle achieved full closure in 67% (4 of 6) and 50% (3 of 6) of trials with the 60 × 18-mm and 100×18-mm retractors, respectively. Median ease-of-use scores with the 60×18-mm and 100×18-mm retractors, respectively, were 4.5 (range, 4-5) and 4.5 (range, 3-5) for the Spine Scorpion, and both 1.0 (range, 1-2) for the curved needle. CONCLUSION: Results from this laboratory investigation using a suture passer for thoracolumbar fascia closure show a significant reduction in closure time and completion of the procedure compared to a conventional curved needle.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。