Iatrogenic sciatic nerve injury due to cerclage wiring for proximal periprosthetic femoral fracture: A rare case report

因股骨近端假体周围骨折环扎钢丝导致医源性坐骨神经损伤:一例罕见病例报告

阅读:2

Abstract

Cerclage wiring is used to reinforce the stability of fractures and optimize plate fixations for femoral fractures such as periprosthetic fractures. However, cerclage wiring requires attention to neurovascular structures to prevent injuries. We have presented a case of iatrogenic sciatic nerve injury after osteosynthesis with cerclage wiring. A 71-year-old woman underwent osteosynthesis with cerclage wiring for a proximal periprosthetic femoral fracture. Immediately after the operation, the patient developed motor and sensory disorders, particularly in the sciatic nerve area, leading to a suspicion of nerve injury. Consequently, reoperation showed that the right sciatic nerve was strangulated by the cerclage wire, but the nerve was functional. Since the sciatic nerve was partially continuous and retained sensation to some extent, strangulation release was performed. Subsequently, both sensory and motor disorders improved. This case suggests that attention should be given to not only the blood vessels in the anterior region but also the sciatic nerve in the posterior region when performing cerclage wiring for femoral fractures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。