A Modified Triangular Arthroscopic Suture-Based Fixation for Tibial Eminence Fractures: Technique, Outcome and Literature Review

改良三角关节镜缝合固定术治疗胫骨髁间隆突骨折:技术、疗效及文献综述

阅读:1

Abstract

Objectives: Tibial eminence fractures account for 2% to 5% of all knee injuries. Low-grade fractures, such as Type I, are typically treated conservatively, whereas high-grade fractures, such as Types III and IV, usually require surgical intervention. This paper describes a modified surgical arthroscopic technique, which employs pull-through triangle suture fixation for Type II and Type III arthroscopic intercondylar eminence avulsion fractures. In addition, we examined the efficacy and complication rate compared to the existing literature. Methods: Data were prospectively collected for knee arthroscopy surgeries and retrospectively analyzed with a minimum two-year follow-up. Twenty-three consecutive adults underwent arthroscopic treatment of displaced intercondylar Type II and Type III eminence fractures, as evidenced by clinical examination and imaging studies between May/2008 and May/2021. The patient's knee evaluation was performed using clinical symptoms and physical examination, along with International Knee Documentation Committee (IKDC) questionnaire and Tegner Activity Score. Compared to the literature, post-hoc power was calculated based on the mean Tegner Activity Score in our analysis. Results: fifteen females and eight males (mean age 33.9 years, range 19-56 years) were enrolled. The average postoperative follow-up was 35.4 months (27-53). The post-hoc power was 95% confidence in terms of the Tegner Activity Score. The mean ± standard deviation postoperative Tegner Activity Score was 8.2 ± 1.7 (6.8-10.0). Fifteen patients were classified as IKDC A (normal), six as IKDC B (nearly normal), and two as IKDC C (abnormal). The mean IKDC subjective score was 72.7 ± 23 (23-100). Twenty-four patients achieved normal flexion degrees compared with the unaffected side, while one patient achieved a flexion of only 0-90°. The group's mean flexion range of motion was 123 ± 16° (90-150°). Conclusion: This study presents a modified surgical arthroscopic suture fixation technique for tibial eminence fractures. The procedure is relatively simple and requires no more than basic arthroscopy equipment. The clinical and radiographic results indicate that this technique is safe, efficient, enables early initiation of rehabilitation, and has a lower complication rate in a variety of aspects compared with other fixation techniques used for tibial eminence fractures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。