Impact of prosthesis oversizing on clinical outcomes of transcatheter aortic valve implantation using a self-expandable Evolut R valve

假体尺寸过大对经导管主动脉瓣置换术(使用自膨胀式 Evolut R 瓣膜)临床结果的影响

阅读:2

Abstract

BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) has a growing target population after being indicated even in low-surgical-risk patients with severe symptomatic aortic stenosis. However, postoperative outcomes can be compromised due to para-valvular leakage (PVL). A lot of procedural steps have been investigated to decrease this partially avoidable operational hazard. Oversizing is a main technique to decrease the PVL, despite being itself a risky step. Many studies have been conducted to identify the optimum degree of oversizing. However, studies about oversizing by more than 20% are scarce. We aimed to evaluate the safety and efficacy of oversizing equal to or more than 20%. RESULTS: 209 patients who underwent TAVI using the self-expandable valve Evolut R were initially included. 66 patients were excluded because of the baseline conduction disturbance and lack of sufficient data, so 143 patients, 60 females and 83 males, were enrolled in our study as two groups based on the degree of oversizing: Group A included 97 patients with an oversizing index (OI) of less than 20%, and Group B included 46 patients with an OI of 20% or more. We conducted a new technique for more accurate measuring of the OI in the context of the implantation depth, and our patients were categorized using this technique. Our findings have met our primary end point in terms of the safety and efficacy of oversizing by 20% or more. There was no significant difference between both groups in terms of new-onset conduction disturbance (NOCD), with zero cases of annular rupture or coronary encroachment. In terms of efficacy, The incidence of significant PVL (grade 2 or more) in group B was less than in group A (P value 0.007). The ROC curve found that the minimum depth of implantation-derived oversizing (DIDO) to predict no significant PVL was less than 17%. CONCLUSION: Prosthesis oversizing by 20% using the self-expandable Evolut R valve is safe and effective, with no significant effect on the conduction system, coronary encroachment, or annular injury, and warrants a greater reduction in the incidence of significant PVL.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。