Investigating the ability of non-invasive measures of cardiac output to detect a reduction in blood volume resulting from venesection in spontaneously breathing subjects

研究无创性心输出量测量方法检测自主呼吸受试者因静脉切开术导致血容量减少的能力

阅读:1

Abstract

BACKGROUND: Monitoring cardiac output (CO) in shocked patients provides key etiological information and can be used to guide fluid resuscitation to improve patient outcomes. Previously this relied on invasive monitoring, restricting its use in the Emergency Department (ED) setting. The development of non-invasive devices (such as LiDCOrapid(v2) with CNAP™ and USCOM 1A), and ultrasound based measurements (Transthoracic echocardiography, inferior vena cava collapsibility index (IVCCI), carotid artery blood flow (CABF) and carotid artery corrected flow time (FTc)) enables stroke volume (SV) and CO to be measured non-invasively in the ED. We investigated the ability of these techniques to detect a change in CO resulting from a 500 ml reduction in circulating blood volume (CBV) following venesection in spontaneously breathing subjects. Additionally, we investigated if using incentive spirometry to standardise inspiratory effort improved the accuracy of IVC based measurements in spontaneously breathing subjects. METHODS: We recorded blood pressure, heart rate, IVCCI, CABF, FTc, transthoracic echocardiographic (TTE) SV and CO, USCOM 1A SV and CO, LIDCOrapidv2 SV, CO, Stroke volume variation (SVV) and pulse pressure variation (PPV) in 40 subjects immediately before and after venesection. The Log-Odds and coefficient of variation of the difference between pre- and post-venesection values for each technique were used to compare their ability to consistently detect CO changes resulting from a reduction in CBV resulting from venesection. RESULTS: TTE consistently detected a reduction in CO associated with venesection with an average decrease in measured CO of 0.86 L/min (95% CI 0.61 to 1.12) across subjects. None of the other investigated techniques changed in a consistent manner following venesection. The use of incentive spirometry improved the consistency with which IVC ultrasound was able to detect a reduction in CBV. CONCLUSIONS: In a population of spontaneously breathing patients, TTE is able to consistency detect a reduction in CO associated with venesection.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。