Resection of Eloquent Located Brain Tumors by Mapping Only-A Feasibility Study

仅通过定位切除位于重要功能区的脑肿瘤——一项可行性研究

阅读:1

Abstract

BACKGROUND: Patients with eloquently located cerebral lesions require surgery that usually employs mapping and monitoring techniques for the preservation of motor and language function. However, in many cases, mapping only might be sufficient, reducing the need for technical and personnel logistics. Here, we report our experiences using a device that can be operated by the surgeon independently, providing mapping techniques but omitting monitoring techniques. METHODS: For monopolar and bipolar cortical/subcortical stimulation, pre-set programs were available and intraoperatively used-two enabling EMG real-time tracking of eight muscles for monopolar (cortical/subcortical) mapping, and two programs for 60 Hz stimulation, one with EMG and one without. Motor mapping was performed under continuous observation of the screened EMG signal and acoustic feedback by the surgeon. For the 60 Hz stimulation, a standard bipolar stimulation probe was connected through a second port. The preoperative application of the subdermal EMG needles, as well as the intraoperative handling of the device, were performed by the surgeons independently. Postoperatively, an evaluation of the autonomous handling and feasibility of the device for the chosen test parameters was conducted. RESULTS: From 04/19-09/21, 136 procedures in patients with eloquently located cerebral lesions were performed by using the "mapping-only" device. Mapping was performed in 82% of the monopolar cases and in 42% of the bipolar cases. Regarding the setup and sufficiency for the cortical/subcortical mapping, the device was evaluated as independently usable for motor and language mapping in 129 procedures (95%). Gross total resection was achieved, or functional limit throughout resection was reached, in 79% of the patients. 13 patients postoperatively suffered from a new neurological deficit. At the 3-6-month follow-up, three patients showed persistent deficit (2%). All of them had language disturbances. The setup time for the device was less than 7 min. CONCLUSIONS: The device was evaluated as sufficient in over 90% of cases concerning monopolar and bipolar mapping, and the setup and handling was sufficient in all patients. With the present data we show that in well-selected cases, a very simple system providing mapping only is sufficient to achieve gross total resection with the preservation of functionality.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。