The accuracy of "subacromial grind test" in diagnosis of supraspinatus rotator cuff tears

“肩峰下研磨试验”在诊断冈上肌肩袖撕裂中的准确性

阅读:2

Abstract

PURPOSE: The aim of this study is to assess the accuracy of a simple clinical test (subacromial grind test) in diagnosing supraspinatus tendon tears. PATIENTS AND METHODS: The test is considered positive if palpable crepitus or grinding is detected on passive internal and external rotation of the shoulder while abducted in the scapular plane. Data were collected prospectively on 47 patients undergoing shoulder arthroscopy, and the results of the test and arthroscopy compared. RESULTS: During arthroscopy, 17 patients had full thickness (FT) tears of supraspinatus tendon and 10 had partial thickness tears. For any supraspinatus tear, the sensitivity of the test was 63%, specificity 95%, positive predictive value 94%, negative predictive value 66% and overall accuracy 79%. For FT tears, the sensitivity was 82%, specificity 87%, positive predictive value 78%, negative predictive value 90% and overall accuracy 85%. CONCLUSION: We found that this is a useful single test for diagnosing FT supraspinatus tears. LEVEL OF EVIDENCE: Level IV diagnostic study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。