Diagnostic performance of EfficientNetV2-S method for staging liver fibrosis based on multiparametric MRI

基于多参数磁共振成像的EfficientNetV2-S方法在肝纤维化分期中的诊断性能

阅读:1

Abstract

PROBLEM: Previous studies had confirmed that some deep learning models had high diagnostic performance in staging liver fibrosis. However, training efficiency of models predicting liver fibrosis need to be improved to achieve rapid diagnosis and precision medicine. AIM: The deep learning framework of EfficientNetV2-S was noted because of its faster training speed and better parameter efficiency compared with other models. Our study sought to develop noninvasive predictive models based on EfficientNetV2-S framework for staging liver fibrosis. METHODS: Patients with chronic liver disease who underwent multi-parametric abdominal MRI were included in the retrospective study. Data augmentation methods including horizontal flip, vertical flip, perspective transformation and edge enhancement were applied to multi-parametric MR images to solve the data imbalance between different liver fibrosis groups. The EfficientNetV2-S models were used for the prediction of liver fibrosis stages F1-2, F1-3, F3, F4 and F3-4. We evaluated the diagnostic performance of our models in training, validation, and test sets by using receiver operating characteristic curve (ROC) analysis. RESULTS: The total training time of EfficientNetV2-S was about 6 h. For differentiating of F1-2 vs F3, the accuracy, sensitivity and specificity of EfficientNetV2-S model were 96.2 %, 96.4 % and 96.0 % in the test set. The AUC in test set was 0.559. The accuracy, sensitivity and specificity were 82.1 %, 74.5 % and 89.6 % in the test set by using EfficientNetV2-S model to differentiate F1-2 vs F3-4, and the AUC in test set were 0.763. For differentiating F1-3 vs F4, the accuracy, sensitivity and specificity of EfficientNetV2-S model were 71.5 %, 73.4 % and 69.5 % in the test set. The AUC was 0.553 in test set. For differentiating F1-2 vs F4, the accuracy, sensitivity and specificity of our model were 84.3 %, 80.2 % and 88.3 % in the test set, and the AUC was 0.715, respectively. For differentiating F3 vs F4, the accuracy, sensitivity and specificity of EfficientNetV2-S model were 92.5 %, 89.1 % and 95.6 % in the test set, and the AUC was 0.696 in the test set. CONCLUSIONS: The EfficientNetV2-S models based on multi-parametric MRI had the feasibility for staging of liver fibrosis because they showed high training speed and diagnostic performance in our study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。