Single-tube mixed agglutination test for the detection of staphylococcal protein A

用于检测葡萄球菌蛋白A的单管混合凝集试验

阅读:1

Abstract

A simple, rapid mixed agglutination test using sheep erythrocytes (SRBC) sensitized with rabbit hemolysin and intact viable staphylococci is described for the detection of bound staphylococcal protein A. Soluble protein A was heat extracted from 50 clinical isolates as well as the Cowan I and Wood 46 strains of Staphylococcus aureus and titered by a hemagglutination test using sensitized SRBC and dilutions of soluble protein A. Protein A could be detected in all of these supernatants including that of S. aureus Wood 46, a strain generally considered to be protein A negative. These organisms were later retested by the mixed agglutination test and even those staphylococcal isolates expressing very low heat-extractable soluble protein A concentrations (1:2 titers) were positive, confirming the sensitivity of the test. In a screen of clinical isolates, only 4 of 235 (1.8%) coagulase-positive isolates were negative in the mixed agglutination test. Of 25 coagulase-negative isolates, none yielded a positive reaction.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。