Validation and reliability of the rapid diagnostic test 'SD Bioeasy Dengue Duo' for dengue diagnosis in Brazil: a phase III study

在巴西开展的登革热快速诊断试剂盒“SD Bioeasy Dengue Duo”的验证和可靠性研究:一项III期临床试验

阅读:2

Abstract

BACKGROUND: The diagnosis of dengue is complex. Until recently, only specialised laboratories were able to confirm dengue infection. However, this has changed with the newly available immunochromatographic rapid tests. Early diagnosis is of great interest, and point-of-care rapid tests have been increasingly used in Brazil. Most of those tests have not undergone validation in the Brazilian population. In this context, we decided to evaluate a rapid test introduced in the Federal District (FD). OBJECTIVES: To estimate the accuracy and reliability of the SD Bioeasy Dengue Duo rapid test and its components to detect dengue infections in a consecutive sample of symptomatic residents in the FD, Brazil. METHODS: In total, 1353 venous blood samples were collected between 2013 and 2014. Two hundred and six positive samples (cases) and 246 negative samples (non cases) were required for sensitivity and specificity estimation, respectively; for agreement evaluation, we used 401 samples. The reference standard used was a composite of MAC-ELISA, virus isolation and real-time polymerase chain reaction (RT-qPCR). The evaluation was conducted prospectively under field conditions in the public health units of the FD. FINDINGS: The results for the overall accuracy of the rapid test (NS1/IgM combined) showed 76% sensitivity and 98% specificity. The sensitivity for the NS1 component (67%) was better than that for the IgM component (35%). The positive likelihood ratio was 46, and the negative likelihood ratio was 0.24. The reliability of the test (NS1/IgM combined) demonstrated crude agreement of 98% (Kappa index 0.94). MAIN CONCLUSIONS: The present phase III, large-scale validation study demonstrates that the rapid test SD Bioeasy Dengue Duo has moderate sensitivity (NS1/IgM combined) and high specificity. Therefore, the test is useful in confirming the diagnosis of dengue, but not enough to rule out the diagnosis. Our results also suggest that Dengue virus (DENV) viral load estimated through the RT-qPCR and antibody level measured through the MAC-ELISA could have had a direct influence on the accuracy of the rapid test.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。