Application of measurable surgical guides in immediate implant placement and immediate restoration

可测量手术导板在即刻种植和即刻修复中的应用

阅读:1

Abstract

This article reports a case of using immediate implant placement and immediate restoration combined with measurable implant surgical guides to restore compromised maxillary incisors caused by dental trauma. Target restoration was designed in the exoCAD software preoperatively, intraoral measurements were obtained in three directions, and the correct position of virtual implants was determined in BlueSky Plan 4. Afterward, measurable implant guides were designed and fabricated by 3D printing. Under the guidance of the measurable implant surgical guides and intraoperative measurement, the entry point was determined, the axial direction was verified when drilling to half the depth, and the 3D position was verified when drilling to total depth. Implants were inserted followed by verification once again. The temporary restoration, which was designed based on the target restoration and emergence profile of the original teeth and milled preoperatively, was connected to the implant immediately after surgery. Postoperative accuracy analysis showed that the mean linear deviations between the actual implant position and the pre-planned position were (0.57±0.17) mm at the entry point and (0.82±0.27) mm at the apex, and the mean angular deviation was (1.86±0.89) °, demonstrating that precise implant placement and immediate restoration were implemented.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。