Initial Experiences with a 980 nm Diode Laser for Photoselective Vaporization of the Prostate for the Treatment of Benign Prostatic Hyperplasia

980纳米二极管激光用于前列腺光选择性汽化治疗良性前列腺增生的初步经验

阅读:1

Abstract

PURPOSE: This study was conducted to analyze the efficacy of photoselective vaporization of the prostate (PVP) with the use of a 980 nm diode laser for benign prostatic hyperplasia (BPH) according to postoperative period. MATERIALS AND METHODS: Data were collected from 96 patients who were diagnosed with BPH and who underwent PVP with the 980 nm K2 diode laser. Postoperative parameters, including International Prostate Symptom Score (IPSS), quality of life (QoL) score, maximum urinary flow rate (Qmax), and post-void residual volume (PVR), were assessed and compared with preoperative baseline values. RESULTS: The mean prostate volume was 45.3±15.6 g, the mean operative time (lasing time) was 22.9±18.3 minutes, the total amount of energy was 126±84 kJ, and the Foley catheter maintenance period after PVP was 24.8±5.6 hours. At 1 month, significant improvements were noted in IPSS (11.7±6.6), QoL score (2.3±1.1), Qmax (12.7±6.1 ml/sec), and PVR (41.9±30.5 ml). After 3 months, all follow-up parameters showed significant improvements that were sustained throughout a period of 6 months after PVP. CONCLUSIONS: PVP using a K2 diode laser is a minimally invasive and effective surgical method for improvement of BPH and is associated with minimal morbidity.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。