Biological mechanisms of infection resistance in tissue engineered blood vessels compared to synthetic expanded polytetrafluoroethylene grafts

组织工程血管与合成膨体聚四氟乙烯移植物抗感染的生物机制比较

阅读:7
作者:Juan Wang, Shelby K F Blalock, Garyn S Levitan, Heather L Prichard, Laura E Niklason, Robert D Kirkton

Conclusions

The HAV material seems to demonstrate a resistance to bacterial infection. This infection resistance is likely due to the HAV's native-like material composition, which may be more biocompatible with host neutrophils than synthetic vascular graft material.

Methods

A phase III comparative clinical study between investigational HAVs (n = 177) and commercial ePTFE grafts (n = 178) used for hemodialysis access (ClinicalTrials.gov Identifier: NCT02644941) was evaluated for conduit infection rates followed by histological analyses of HAV and ePTFE tissue explants. The clinical histopathology of HAV and ePTFE conduits reported to be infected was compared with immunohistochemistry of explanted materials from a preclinical model of bacterial contamination. Mechanistic in vitro studies were then conducted using isolated human neutrophils seeded directly onto HAV and ePTFE materials to analyze neutrophil viability, morphology, and function.

Objective

Synthetic expanded polytetrafluoroethylene (ePTFE) grafts are known to be susceptible to bacterial infection.

Results

Clinical trial results showed that the HAV had a significantly lower (0.93%; P = .0413) infection rate than that of ePTFE (4.54%). Histological analysis of sections from infected grafts explanted approximately 1 year after implantation revealed gram-positive bacteria near cannulation sites. Immunohistochemistry of HAV and ePTFE implanted in a well-controlled rodent infection model suggested that the ePTFE matrix permitted bacterial infiltration and colonization but may be inaccessible to neutrophils. In the same model, the HAV showed host recellularization and lacked detectable bacteria at the 2-week explant. In vitro results demonstrated that the viability of human neutrophils decreased significantly upon exposure to ePTFE, which was associated with neutrophil elastase release in the absence of bacteria. In contrast, neutrophils exposed to the HAV material retained high viability and native morphology. Cocultures of neutrophils and Staphylococcus aureus on the conduit materials demonstrated that neutrophils were more effective at ensnaring and degrading bacteria on the HAV than on ePTFE. Conclusions: The HAV material seems to demonstrate a resistance to bacterial infection. This infection resistance is likely due to the HAV's native-like material composition, which may be more biocompatible with host neutrophils than synthetic vascular graft material.