Antimicrobial peptides in human synovial membrane as (low-grade) periprosthetic joint infection biomarkers

人滑膜中的抗菌肽作为(低级别)假体周围关节感染的生物标志物

阅读:2

Abstract

BACKGROUND: Safe diagnosis of periprosthetic joint infection (PJI) is of utmost importance for successful exchange arthroplasty. However, current diagnostic tools show insufficient accuracy in the clinically common and challenging chronic low-grade infections. To close this diagnostic gap, reliable (bio)markers display the most promising candidates. Antimicrobial peptides (AMPs) are part of the innate immune response towards microbial growth. Recently we could show significant intraarticular levels of human cathelicidin LL-37 and β-defensin-3 (HBD-3) with high diagnostic accuracy in PJI synovial fluid. Consequently, these promising biomarkers were evaluated in PJI synovial membrane and synoviocytes, which may significantly facilitate histological diagnosis of PJI to improve outcome of septic joint replacement. METHODS: In this prospective single-center controlled clinical study (diagnostic level II), consecutive patients with total hip (THR) and knee (TKR) replacements were included undergoing primary arthroplasty (n = 8), surgical revision due to aseptic loosening (n = 9) and septic arthroplasty with coagulase-negative staphylococci (n = 8) according to the criteria of the Musculoskeletal Infection Society (MSIS). Semiquantitative immunohistochemical (IHC) analysis of LL-37, HBD-3 and HBD-2 in synovial membrane and isolated synoviocytes based on Total Allred Score (TS) and Immunoreactive Remmele and Stegner score (IRS) was performed. For statistical analysis, SPSS 26.0/R3.6.3 (p < 0.05) was used. RESULTS: The AMPs LL-37 and HBD-3 were significantly elevated (up to 20×) in synovial membranes from PJI compared to aseptic loosening or primary arthroplasty. The area under the curve (AUC) in a receiver operating characteristic curve analysis was equal to 1.0 for both scores revealing excellent diagnostic accuracy. Isolated synoviocytes as cellular AMP source showed comparable results with a significant LL-37/HBD-3-increase up to 3 × in PJI. In contrast, local HBD-2 levels were negligible (p > 0.23) upon PJI with a lower diagnostic accuracy (AUC = 0.65) in analogy to our previous findings with synovial fluid. CONCLUSIONS: Our results implicate AMPs as promising and specific biomarkers for the histological diagnosis of PJI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。