Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients

种植体周围粘膜的炎症基因谱和颗粒存在情况:针对 9 名患者的初步研究

阅读:8
作者:Julia Olander, Sargon Barkarmo, Petra Hammarström Johansson, Ann Wennerberg, Victoria Franke Stenport

Conclusions

Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.

Material and methods

Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads.

Methods

Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads.

Results

In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP - MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group. Conclusions: Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.