Delivering the diluted contrast agent with saline via a spiral flow tube improves arterial enhancement for contrast enhancement of magnetic resonance angiography of the neck: A retrospective study

通过螺旋输液管输送稀释的造影剂和生理盐水可改善颈部磁共振血管造影的动脉增强效果:一项回顾性研究

阅读:1

Abstract

A contrast agent can be pushed by a saline solution more effectively through a spiral flow tube than through a conventional T-shaped tube in contrast-enhanced magnetic resonance angiography (CEMRA). To compare the degree of contrast enhancement and signal stability in the carotid artery by using CEMRA between a spiral flow tube and a T-shaped tube.A total of 100 patients were analyzed in this retrospective study. The first 50 patients underwent CEMRA of the carotid artery with the T-shaped tube, while the last 50 patients used the spiral flow tube. Gadoterate meglumine was diluted with saline to make a total volume of 20 mL. Injection was performed with a bolus rate of 2.5 mL/s for 8 seconds. Five regions of interest (ROIs) were placed on the contrast-enhanced area in each carotid artery and the signal intensity (SI) in the ROI was used for the analysis. The ROIs on the brain stem were also placed and the average SI in this ROI was used as a reference signal. The enhancement of the artery (Eartery) was calculated as a normalized signal using the following equation: Eartery = SI in the ROI of the carotid bifurcation/SI in the ROI of the brain stem. Signal homogeneity in the contrast-enhanced area (SHenhance) was assessed by calculating the coefficient of variation from the SI in the 5 ROIs. The value of SHenhance and Eartery between the data obtained from the spiral flow tube and the T-shaped tube were compared. P-values <.05 were considered significant.We found a significant difference in SHenhance between the data obtained from the spiral flow tube (0.20 ± 0.060) and the T-shaped tube (0.24 ± 0.056) (P = .001). The Eartery values significantly increased by 15% (spiral flow tube, median 14.1 with interquartile range [IQR] 11.8-15.4 vs T-shaped tube, median 12.3 IQR 11.3-14.0, P = .02) using the spiral flow tube.These findings suggest that, by using the Spiral flow tube, the homogeneity of the contrast-enhanced signal intensity in the carotid artery was significantly improved without decreasing the signal intensity in CEMRA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。