Variability measurements provide additional value to shear wave elastography in the diagnosis of pancreatic cancer

变异性测量为剪切波弹性成像在胰腺癌诊断中提供了额外的价值。

阅读:1

Abstract

Shear wave elastography (SWE) is a technique to non-invasively and quantitatively evaluate tissue stiffness. We aimed to investigate whether we can differentiate pancreatic cancer (PC) from normal pancreatic parenchyma (NPP) by SWE using transabdominal ultrasound. We investigated a total of 106 patients (84 with NPP and 22 with PC) whose pancreatic elastic modulus was measured by two-dimensional SWE (2D-SWE). Intra-rater reliability in this study was examined, and three measurements were sufficiently reliable. There were no differences between the two groups in factors that could affect SWE measurements. The median value of the elastic modulus was 5.70 kPa in the PC patients and 5.66 kPa in the NPP group, which was not significantly different (P = 0.785). On the contrary, the range was 8.64 kPa and 4.72 kPa, with a significantly greater range in the PC patients (P = 0.001). In conclusion, the median elastic modulus measured by 2D-SWE was not significantly different between PC and NPP, and evaluating the obtained elastic modulus itself is not useful in differentiation. However, the variability was significantly greater in PC than in NPP. Evaluating the range of elasticities will provide additional information in SWE, which may be useful in the diagnosis of PC.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。