In vivo dosimetry for testicular and scalp shielding in total skin electron therapy using a radiophotoluminescence glass dosimeter

利用放射光致发光玻璃剂量计对全身皮肤电子治疗中的睾丸和头皮进行体内剂量测定

阅读:1

Abstract

Mycosis fungoides (MF) is a common, low-grade non-Hodgkin's lymphoma of skin-homing T lymphocytes that can be treated via skin-directed radiotherapy. Our institution has implemented total skin electron therapy (TSET) with a 4.3 m source-to-surface distance (SSD) and 6 MeV electron beams with a beam spoiler. A 35-year-old male undergoing TSET desired to avoid radiotherapy-induced hair loss and temporary infertility; therefore, leakage dose to scalp and testicles was reduced with a special radiation shield composed of stacked lead sheets. The shields for the scalp and scrotal were of 3 mm and 6 mm, respectively. To assess leakage doses, a radiophotoluminescence glass dosimeter (RPLD) was placed at every fraction. The difference dose between the measured and prescribed dose at the calibration point was 2%. The top of the head and scrotal surface exhibited 18 cGy and 10 cGy, respectively. Thus, the dose to the scrotal surface was not beyond the testicular tolerance dose of 20 cGy. Results of semen analysis two months postradiotherapy were normal. There was no hair loss during or after radiation therapy. Therefore, the RPLD is a useful in vivo dosimeter that provides technical information on radiation shielding to allow for completion of TSET without hair loss or temporary infertility.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。