Do Osteochondroplasty Alone, Intertrochanteric Derotation Osteotomy, and Flexion-Derotation Osteotomy Improve Hip Flexion and Internal Rotation to Normal Range in Hips With Severe SCFE? - A 3D-CT Simulation Study

对于重度股骨头骨骺滑脱症患者,单纯骨软骨成形术、股骨粗隆间旋转截骨术和屈曲旋转截骨术能否改善髋关节屈曲和内旋活动度至正常范围?——一项三维CT模拟研究

阅读:1

Abstract

BACKGROUND: Severe slipped capital femoral epiphysis (SCFE) leads to femoroacetabular impingement and restricted hip motion. We investigated the improvement of impingement-free flexion and internal rotation (IR) in 90 degrees of flexion following a simulated osteochondroplasty, a derotation osteotomy, and a combined flexion-derotation osteotomy in severe SCFE patients using 3D-CT-based collision detection software. METHODS: Preoperative pelvic CT of 18 untreated patients (21 hips) with severe SCFE (slip-angle>60 degrees) was used to generate patient-specific 3D models. The contralateral hips of the 15 patients with unilateral SCFE served as the control group. There were 14 male hips (mean age 13±2 y). No treatment was performed before CT. Specific collision detection software was used for the calculation of impingement-free flexion and IR in 90 degrees of flexion and simulation of osteochondroplasty, derotation osteotomy, and combined flexion-derotation osteotomy. RESULTS: Osteochondroplasty alone improved impingement-free motion but compared with the uninvolved contralateral control group, severe SCFE hips had persistently significantly decreased motion (mean flexion 59±32 degrees vs. 122±9 degrees, P <0.001; mean IR in 90 degrees of flexion -5±14 degrees vs. 36±11 degrees, P <0.001). Similarly, the impingement-free motion was improved after derotation osteotomy, and impingement-free flexion after a 30 degrees derotation was equivalent to the control group (113± 42 degrees vs. 122±9 degrees, P =0.052). However, even after the 30 degrees derotation, the impingement-free IR in 90 degrees of flexion persisted lower (13±15 degrees vs. 36±11 degrees, P <0.001). Following the simulation of flexion-derotation osteotomy, mean impingement-free flexion and IR in 90 degrees of flexion increased for combined correction of 20 degrees (20 degrees flexion and 20 degrees derotation) and 30 degrees (30 degrees flexion and 30 degrees derotation). Although mean flexion was equivalent to the control group for both (20 degrees and 30 degrees) combined correction, the mean IR in 90 degrees of flexion persisted decreased, even after the 30 degrees combined flexion-derotation (22±22 degrees vs. 36 degrees±11, P =0.009). CONCLUSIONS: Simulation of derotation-osteotomy (30 degrees correction) and flexion-derotation-osteotomy (20 degrees correction) normalized hip flexion for severe SCFE patients, but IR in 90 degrees of flexion persisted slightly lower despite significant improvement. Not all SCFE patients had improved hip motion with the performed simulations; therefore, some patients may need a higher degree of correction or combined treatment with osteotomy and cam-resection, although not directly investigated in this study. Patient-specific 3D-models could help individual preoperative planning for severe SCFE patients to normalize the hip motion. LEVEL OF EVIDENCE: III, case-control study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。