Fractal analysis at varying locations of clinically failed zirconia dental implants

对临床失败的氧化锆种植体不同位置进行分形分析

阅读:1

Abstract

OBJECTIVES: Previous studies have shown that the fracture toughness of ceramics can be determined from the fractal dimensions (D) of their fracture surfaces and that the surface should be leveled to obtain an accurate D measurement. This study was to determine the effects of leveling operations and distance from the failure origin on the D values. METHODS: Twelve clinically failed zirconia implants from four different manufacturers: Axis Biodental (n=7), Z-Systems (n=3), Straumann (n=1), and Swiss Dental Solutions (n=1) were obtained from one of the authors and thoroughly cleaned. Epoxy replicas were made of three locations along the crack path in the center region of each fracture surface (near origin (O), hackle (H), and near compression curl (CC)) using a light body polyvinyl siloxane impression material. Surfaces were scanned in ScanAsyst mode with a scan size of 5μm×5μm and a scan rate of 0.592Hz using the atomic force microscope. The surface scans were then leveled using 1st order flattening operation in the AFM analysis software. The height data before and after the operation were imported into a custom MathCAD script, and FRACTALS software was used to determine the D value by Minkowski Cover algorithm, which was shown previously to be the algorithm with the highest precision. A Wilcoxon signed-rank test, two-way repeated-measures ANOVA, and one-way repeated-measures ANOVA were performed as detailed below. RESULTS: The data were not normally distributed (S-W p≤0.05), so a non-parametric repeated measures test (Wilcoxon signed-rank test) was selected. The median D values before and after leveling were 2.161 and 2.174, respectively. There was a significant difference before and after leveling (p<0.001). The two-way repeated-measures ANOVA showed no significant difference among the D values for different implant brands (p=0.66) and scanning locations on the fracture surface (p=0.83). After eliminating the implant brand as a factor, the data passed normality and equal variance tests (S-W p=0.88, BF p=0.15). The mean D values and standard deviations from the three locations (O, H, CC) were 2.183±0.031, 2.179±0.024, and 2.175±0.018, respectively. One-way repeated measures ANOVA showed no significant effect of scanning location (p=0.74). SIGNIFICANCE: The leveling operation successfully removed the tilt without decreasing surface tortuosity, as it increased the D values significantly. The fractal dimension was the same at the three locations on the fracture surfaces. This means that hackle and compression curl regions can be used to determine fracture toughness when the failure origin has been lost.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。