Tuning the selectivity and sensitivity of an OmpG nanopore sensor by adjusting ligand tether length

通过调节配体束缚长度来调节 OmpG 纳米孔传感器的选择性和灵敏度

阅读:18
作者:Monifa A Fahie, Bib Yang, Bach Pham, Min Chen

Abstract

We have previously shown that a biotin ligand tethered to the rim of an OmpG nanopore can be used to detect biotin-binding proteins. Here, we investigate the effect of the length of the polyethylene glycol tether on the nanopore's sensitivity and selectivity. When the tether length was increased from 2 to 45 ethylene repeats, sensitivity decreased substantially for a neutral protein streptavidin and slightly for a positively charged protein (avidin). In addition, we found that two distinct avidin binding conformations were possible when using a long tether. These conformations were sensitive to the salt concentration and applied voltage. Finally, a longer tether resulted in reduced sensitivity due to slower association for a monoclonal anti-biotin antibody. Our results highlight the importance of electrostatic, electroosmotic and electrophoretic forces on nanopore binding kinetics and sensor readout.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。